| Deliverable number | Deliverable description | Deliverable type |
| D1 | Comparison report of primary absorbed dose standards for clinical scanning UHDR proton beams. This includes: (i) the characterisation and determination of correction factors of existing primary standards for UHDR conditions, (ii) a sensitivity analysis of characteristics and correction factors on beam parameters, and (iii) target uncertainties compared to those in international CoPs for conventional clinical radiotherapy | Comparison report |
| D2 | Report on the use of open-source software for the simulation of secondary standard ionisation chamber recombination correction factors in clinical UHDR proton and UHDPP electron beams using (i) the temporal structure of these beams as input, (ii) their validation with measurements and (iii) their application to sensitivity analysis and uncertainty evaluation | Report |
| D3 | Document on a data set of measured and simulated ks and kQ correction factors for scanning UHDR proton beams | Document |
| D4 | Recommendations on how to extend the reference dosimetry methodology of existing CoPs to scanning UHDR proton beams with target uncertainties similar to existing CoPs. This includes (i) measurement of beam characteristics, (ii) determination of dose-rate parameters, (iii) calibration of secondary standards against portable primary standards, (iv) measurement of ks and kQ correction factors for secondary standards, (v) assessment of the suitability of secondary standards, and (vi) the derivation of traceability routes | Recommendations |
| D5 | Document on a data set of measured and simulated ks and kQ correction factors for UHDPP electron beams | Document |
| D6 | Recommendations on how to extend existing CoPs for reference dosimetry to UHDPP electron beams intended for clinical use with target uncertainties similar to existing CoPs. This includes (i) the measurement of beam characteristics, (ii) an assessment of the suitability of secondary standards, and (iii) the derivation of traceability routes | Recommendations |
| D6 | Document on a data set of measured and simulated ks and kQ correction factors for UHDPP electron beams | Document |
| D7 | Evidence of contributions to or influence on new or improved international guides, recommendations and standards with a specific focus on the following guides and committees: AAPM TG-359, IEC/SC62, BIPM CCRI(I), DIN NAR, IAEA, IPEM, NCS, ESTRO, EFOMP. Examples of early uptake of project outputs by end-users. Updated dissemination, communication and exploitation plan. | Reporting documents |
| D8 | Delivery of all technical and financial reporting documents as required by EURAMET | Reporting documents |